SPECIFICATIONS OF THE BUILDING
|
FOUNDATION |
Reinforced Concrete foundation system to Engineer’s Requirements
|
SUPERSTRUCTURE |
Reinforced concrete, Steel Frame and Steel Roof Rafters trusses / purlins
|
|
ROOF SYSTEMS |
- Pitched roof
|
Metal Roof c/w Insulation, Structural Steel
|
- Flat roof
|
Reinforced concrete roof c/w waterproofing system
|
- Gutter & Rain Water Goods
|
Stainless steel gutter & UPVC Pipe
|
|
FLOOR DESIGN LOADS |
- Ground Floor Production Area
|
20KN/m2, non-suspended floor slab
|
- 1st or 2nd Floor Production Area
|
10 KN/m2
|
- General Office
|
4 KN/m2
|
|
WALL & FINISHES |
Reinforced concrete walls and/or Pre-cast walls and/or Brick wall, plaster & painted with paint
|
|
Pre-finished metal walling
|
|
Ceramic wall tiles to Toilets (2.1m high)
|
|
FLOORS & FINISHES |
- Ground Floor
|
Reinforced concrete with damp proof membrane.
|
- Production Area
|
RC Slab with approved floor hardener
|
- Toilets
|
Ceramic tiles as per Consultants specification
|
Office & Lobby Finishes
|
Polished Ceramic tiles as per Consultants specification
|
|
CEILING
|
- Production Area
|
Exposed Structure (No false ceiling)
|
- General & Production Office Area
|
1200 x 600mm Mineral Board Ceiling
|
|
WINDOWS
|
Aluminum framed with tinted glass consist of top hung, casement and fixed glass windows
|
|
DOORS
|
- External Doors
|
Motorized Roller Shutters, Metal Doors and Tempered Glass Door (Front entrances)
|
- Internal Doors
|
Timber flush doors and Fire Rated Doors
|
|
SANITARY & WATER SUPPLY INSTALLATION
|
WC, Hand Basin, Taps and Water Tank
|
ELECTRICAL SERVICES
|
Electrical power supply 300Amp or 400Amp
|
|
Electrical supply to the main switch board only. Sufficient lighting points and basic light fittings
|
|
INFRASTRUCTURE WORKS (within compound)
|
- External Road
|
Reinforced Concrete Road c/w Road Marking
|
- Parking Bays
|
Reinforced Concrete Road c/w Road Lot Marking
|
- Fencing
|
1.8m high brick wall c/w plaster and/or paint and galvanized mesh fencing
|
- Gate
|
6.0m wide Metal sliding gate |